Seite 1 - INSTALLATION & USER GUIDE

INSTALLATION & USER GUIDE Revision 2.0 Revision 2.0

Seite 2 - Ontario • Canada • N2N 3H8

9 Figure 6 Camera Routing Card (CR16) The camera routing card is an optional add on card within the SS16 module. It facilitates the connection of UT

Seite 3 - FCC Information

10System Accessories System Accessory Feature Summary Station Model # Station Feature CS50 CS100 CS150 HS100 HS120 Single Gang Stainless Steel

Seite 4 - TABLE OF CONTENTS

11CS50 Call Station A CS50 is a basic single gang stainless steel call station with a rocker switch. The switch provides for a momentary call and lo

Seite 5 - System Overview

12CS150 Call Station A CS150 is an enhanced single gang stainless steel call station with an epoxy coated silicon call and privacy button, both of w

Seite 6 - Central cabinet (CH1000)

13HS120 Handset/Call Station A HS120 is a basic double gang stainless steel combination handset and call station. The rocker switch provides for a

Seite 7

14System Installation CH1000 Cabinet Mounting The CH1000 cabinet is designed for mounting on a wall. The diagram below shows the location of the fo

Seite 8

15CH1000 Cabinet Features Figure 14 below shows an internal picture of the CH1000 system. All field wiring enters the cabinet from the bottom via du

Seite 9

16System Power Wiring Each CH1000 system is provided with a standard 6 ft line cord which mates with the 120 VAC socket on the bottom edge of the c

Seite 10 - Camera Routing Card (CR16)

17CH1000 Connections The figure below shows all of the connections required to the MI100 Main Interface board found inside the CH1000 cabinet.

Seite 11 - System Accessories

18SS16 Mounting The SS16 is designed to be located in a hallway or corridor of a building in a location near devices that will connect to it. The c

Seite 12 - CS100 Call Station

CAREHAWK INC. CH1000 Installation & User Guide  CareHawk Inc. 229 Westforest Trail • Kitchener Ontario • Canada • N2N 3H8 Phone 519.745.2226

Seite 13 - HS100 Handset

19 CH1000 to SS16 Wiring The wire required for connection from the CH1000 cabinet to all SS16’s is standard CAT3,5, or 5e 24 AWG cable. All RJ45 co

Seite 14 - HS120 Handset/Call Station

20SS16 to End Devices The SS16 allows for connection of up to 16 devices. The devices can be any of the REDy Corp standard stations listed in table

Seite 15 - System Installation

21CS50 Wiring Figure 20 Connection to this station from an SS16 port can be done through an RJ-45 terminated CAT-5 cable (straight through, not cros

Seite 16 - System Power Requirements

22GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC

Seite 17 - System Power Wiring

23GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC

Seite 18 - CH1000 Connections

24GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC

Seite 19 - SS16 Mounting

25HS120 Wiring Connection to this station from the SS16 is done via RJ-45 plug. Connections to the audio transformer are done by crimpin

Seite 20 - CH1000 to SS16 Wiring

26CR16 Installation The CR16 is intended to be installed within the SS16 chassis. When ordering an SS16, it is possible to have it shipped from the

Seite 21 - SS16 to End Devices

27No ConnectNo ConnectNo ConnectTIPRING16 VAC16 VACNo ConnectDA1 PORT 1RJ-45 JACK(1)(2)(3)(4)(8)(7)(6)(5)RJ-45 JACKPIN #No ConnectNo ConnectNo Conne

Seite 22 - CS50 Wiring

28The DA1 is provided with the adapter shown below in figure 28 (model # ADA1). This adapter provides the conversion from RJ45 to RJ11 for connectio

Seite 23 - CS100 Wiring

ii Disclaimer This manual has been validated and reviewed to be accurate for the CH1000 Series Communications System at the time of this manual’s prod

Seite 24 - CS150 Wiring

29General Purpose I/O Connections The general purpose I/O connections are found inside the CH1000 cabinet (See Figure 16 for exact location). The f

Seite 25 - P1 on CS150

30The chart below describes the jumper settings for the ports. The jumpers are found on the MI100 interface board directly behind the I/O terminal s

Seite 26 - HS120 Wiring

31Program Inputs The program inputs are located inside the CH1000 cabinet (See Figure 16 for exact location). Below is the pin outs for the removab

Seite 27 - Camera wiring

32AF125 Amplifier Connections The amplifier connections are made to terminal strips found on the top inside plate in the CH1000 cabinet. Connectio

Seite 28 - : The CH1000

33APPENDIX A NOTE: Numbers 1-4 in the above illustration indicate the twisted pairs in the CAT5 cable. Pin # Wire Color for 568A Wire color for

Seite 29 - PBX Connections

34USER’s GUIDE Basic Operation The CareHawk CH1000 system is designed around keeping things simple. The DA1 phone shown below is the main device use

Seite 30 - Figure 30

35Control Buttons: A Volume key: Adjusts the volume for the handset, headset, and handsfree speaker volume of the ringer tone. There are 8 ringer v

Seite 31

36Phone Commands Dial Sequence Command Dial Sequence 00# Emergency Page All 001…# Emergency Page Inclusive Zones Where … is the list of zon

Seite 32 - Microphone Input

37 033P…# Program Source Inclusive Speakers Where P is the program source ( Program Source : 1?2 - Must be entered as 1 digit ) Where … is the lis

Seite 33 - Master Clock Connections

3TABLE OF CONTENTS System Overview ...4 System Primary Component Overview...

Seite 34 - APPENDIX A

4System Overview AF125 AmplifierCH1000 Central CabinetSecuritySwitching Card(SS16)AnalogC.O.Port(s)PBXMicrophoneEthernetDA1CS100 CallStationSpeakerP

Seite 35 - USER’s GUIDE

5 he CareHawk CH1000 is a distributed, multi-channel, microprocessor-controlled security communication system. The system architecture allows for u

Seite 36 - Control Buttons:

6 The cabinet is made of 18 gauge steel with a durable powder coat finish. The cabinet can be wall or rack-mounted. The overall cabinet dimensions a

Seite 37 - Phone Commands

7 Switching Security Card (SS16) An SS16 adds 16 audio/device ports that provide annunciated call-in with half-duplex communications capabilities be

Seite 38

8 120 watt Power Amplifier (AF125) An AF125 is the external 120 Watt program/paging amplifier used with the system. This unit can be wall mounted or