9 Figure 6 Camera Routing Card (CR16) The camera routing card is an optional add on card within the SS16 module. It facilitates the connection of UT
10System Accessories System Accessory Feature Summary Station Model # Station Feature CS50 CS100 CS150 HS100 HS120 Single Gang Stainless Steel
11CS50 Call Station A CS50 is a basic single gang stainless steel call station with a rocker switch. The switch provides for a momentary call and lo
12CS150 Call Station A CS150 is an enhanced single gang stainless steel call station with an epoxy coated silicon call and privacy button, both of w
13HS120 Handset/Call Station A HS120 is a basic double gang stainless steel combination handset and call station. The rocker switch provides for a
14System Installation CH1000 Cabinet Mounting The CH1000 cabinet is designed for mounting on a wall. The diagram below shows the location of the fo
15CH1000 Cabinet Features Figure 14 below shows an internal picture of the CH1000 system. All field wiring enters the cabinet from the bottom via du
16System Power Wiring Each CH1000 system is provided with a standard 6 ft line cord which mates with the 120 VAC socket on the bottom edge of the c
17CH1000 Connections The figure below shows all of the connections required to the MI100 Main Interface board found inside the CH1000 cabinet.
18SS16 Mounting The SS16 is designed to be located in a hallway or corridor of a building in a location near devices that will connect to it. The c
CAREHAWK INC. CH1000 Installation & User Guide CareHawk Inc. 229 Westforest Trail • Kitchener Ontario • Canada • N2N 3H8 Phone 519.745.2226
19 CH1000 to SS16 Wiring The wire required for connection from the CH1000 cabinet to all SS16’s is standard CAT3,5, or 5e 24 AWG cable. All RJ45 co
20SS16 to End Devices The SS16 allows for connection of up to 16 devices. The devices can be any of the REDy Corp standard stations listed in table
21CS50 Wiring Figure 20 Connection to this station from an SS16 port can be done through an RJ-45 terminated CAT-5 cable (straight through, not cros
22GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC
23GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC
24GNDDATA_ADATA_B+12 VDC INPORT 1-16 CONNECTOR PINOUT+12 VDC INSTATUSINDICATORMODEL: SS161234 12111098 16151413567CH #1 AUDIOCH #1 AUDIOCH #2 AUDIOC
25HS120 Wiring Connection to this station from the SS16 is done via RJ-45 plug. Connections to the audio transformer are done by crimpin
26CR16 Installation The CR16 is intended to be installed within the SS16 chassis. When ordering an SS16, it is possible to have it shipped from the
27No ConnectNo ConnectNo ConnectTIPRING16 VAC16 VACNo ConnectDA1 PORT 1RJ-45 JACK(1)(2)(3)(4)(8)(7)(6)(5)RJ-45 JACKPIN #No ConnectNo ConnectNo Conne
28The DA1 is provided with the adapter shown below in figure 28 (model # ADA1). This adapter provides the conversion from RJ45 to RJ11 for connectio
ii Disclaimer This manual has been validated and reviewed to be accurate for the CH1000 Series Communications System at the time of this manual’s prod
29General Purpose I/O Connections The general purpose I/O connections are found inside the CH1000 cabinet (See Figure 16 for exact location). The f
30The chart below describes the jumper settings for the ports. The jumpers are found on the MI100 interface board directly behind the I/O terminal s
31Program Inputs The program inputs are located inside the CH1000 cabinet (See Figure 16 for exact location). Below is the pin outs for the removab
32AF125 Amplifier Connections The amplifier connections are made to terminal strips found on the top inside plate in the CH1000 cabinet. Connectio
33APPENDIX A NOTE: Numbers 1-4 in the above illustration indicate the twisted pairs in the CAT5 cable. Pin # Wire Color for 568A Wire color for
34USER’s GUIDE Basic Operation The CareHawk CH1000 system is designed around keeping things simple. The DA1 phone shown below is the main device use
35Control Buttons: A Volume key: Adjusts the volume for the handset, headset, and handsfree speaker volume of the ringer tone. There are 8 ringer v
36Phone Commands Dial Sequence Command Dial Sequence 00# Emergency Page All 001…# Emergency Page Inclusive Zones Where … is the list of zon
37 033P…# Program Source Inclusive Speakers Where P is the program source ( Program Source : 1?2 - Must be entered as 1 digit ) Where … is the lis
3TABLE OF CONTENTS System Overview ...4 System Primary Component Overview...
4System Overview AF125 AmplifierCH1000 Central CabinetSecuritySwitching Card(SS16)AnalogC.O.Port(s)PBXMicrophoneEthernetDA1CS100 CallStationSpeakerP
5 he CareHawk CH1000 is a distributed, multi-channel, microprocessor-controlled security communication system. The system architecture allows for u
6 The cabinet is made of 18 gauge steel with a durable powder coat finish. The cabinet can be wall or rack-mounted. The overall cabinet dimensions a
7 Switching Security Card (SS16) An SS16 adds 16 audio/device ports that provide annunciated call-in with half-duplex communications capabilities be
8 120 watt Power Amplifier (AF125) An AF125 is the external 120 Watt program/paging amplifier used with the system. This unit can be wall mounted or